Home > Á¦Ç°¼Ò°³ > R&D Laboratory Equipment (¿¬±¸ & ½ÇÇè¿ë Á¦Ç°) > ÃÊÀ½Æĺлê±â/Æļâ±â-Sonicators/Ultrasonic Processors

ÃÊÀ½Æĺлê±â/Æļâ±â-Sonicators/Ultrasonic ProcessorsÀÌÀüÆäÀÌÁö

Q125

Á¦Á¶»ç
: QSONICA, USA
Cat.No.Description
Q 125 Q 125 Sonicator [°ßÀû¿äû]
4423 2 mm probe, 200 ul - 5 ml [°ßÀû¿äû]
4422 3.2 mm probe, 500 ul - 15 ml [°ßÀû¿äû]
4435 6.4 mm probe, 10 ml - 50 ml [°ßÀû¿äû]
K-0001 Support stand & Clamp [°ßÀû¿äû]
4608 Cup horn [°ßÀû¿äû]
4602 8 tip horn [°ßÀû¿äû]
K-0003 Sound abating enclosure [°ßÀû¿äû]
LSJ150 Support Jack 150 x 150 mm [°ßÀû¿äû]

The Q125 is a microprocessor based, programmable ultrasonic processor.
(Q125´Â ¸¶ÀÌÅ©·ÎÇÁ·Î¼¼¼­¸¦ ÀÌ¿ëÇÑ ÀԷ°ªÀ» ¼³Á¤ÇÏ¿© »ç¿ëÀÌ °¡´ÉÇÑ ÃÊÀ½ÆÄ Æļâ±â/ºÐ»ê±â ÀÔ´Ï´Ù.)

Features include pulse mode and a digital display of both wattage and joules.
(Q125´Â Pulse mode¸¦ ÀÌ¿ëÇØ ÃÊÀ½ÆÄ µ¿ÀÛ ½Ã°£À» Á¶ÀýÇÒ ¼ö ÀÖÀ¸¸ç SampleÀÌ ¹ÞÀº ¿¡³ÊÁö °ªÀÎ Watt ¿Í Joul °ªÀÌ Ç¥½Ã°¡ µË´Ï´Ù.)

The unit is effective for standard cell disruption, DNA/RNA shearing, homogenization and many other applications.
(Q125´Â ¼¼Æ÷ Æļâ, DNA/RNA Àü´Ü, ±ÕÁúÈ­ ¹× ´Ù¸¥ ¸¹Àº ÀÀ¿ë ºÐ¾ß¿¡ Àû¿ëÀÌ µË´Ï´Ù.)

[»ç¿ë ¿ëµµ]
Tissue disruption / homogenization
Cell lysis
DNA shearing
RNA extraction

Programmable operation
Set time and amplitude for hands free operation
(½Ã°£ ¼³Á¤, ¿¡³ÊÁö °­µµ µîÀ» ¼³Á¤ÇÒ ¼ö ÀÖ½À´Ï´Ù.)

Pulse mode
Prevent heat buildup in temperature sensitive samples
(¿Âµµ¿¡ ¹Î°¨ÇÑ sample¿¡ ´ëÇؼ­ °ú´ÙÇÑ ¿­ ¹ß»ý ¹æÁö¸¦ À§ÇØ Pulse¸¦ ÀÌ¿ëÇؼ­ ÃÊÀ½ÆÄ µ¿ÀÛ 1ÃÊ¿¡¼­ 59ÃÊ ¹üÀ§ ³»¿¡¼­ Á¶Àý °¡´ÉÇÕ´Ï´Ù.)

Digital amplitude / intensity control
Output intensity can be set from 20-100%
(¿¡³ÊÁö ¼¼±â¸¦ 20 - 100% Á¶ÀýÀÌ °¡´ÉÇÕ´Ï´Ù.)

Elapsed time indicator
Displays duration of sonication
(¼³Á¤ÇÑ ½Ã°£ °æ°ú¸¦ ³ªÅ¸³»¾î ¾î´À Á¤µµ µ¿ÀÛÀÌ ÀÌ·ç¾î Áö°í ÀÖ´ÂÁö¸¦ È®ÀÎÀÌ °¡´ÉÇÕ´Ï´Ù.)

Display of wattage and joules
Real-time energy monitoring
(Sample¿¡ Àü´ÞµÇ´Â ¿¡³ÊÁö °ªÀ» È®ÀÎ ÇÒ ¼ö ÀÖ½À´Ï´Ù.)

Overload protection
Prevents damage to circuitry if a fault occurs
(¿¡·¯°¡ ¹ß»ýÇßÀ» °æ¿ì, Power supply³»ºÎ ±âÆÇÀ» º¸È£Çϱâ À§ÇØ Overload °æ°í ±â´ÉÀÌ ÀÖ½À´Ï´Ù.)

Compact design
Takes up less space than competitive units
(³ÐÀº °ø°£ÀÌ ÇÊ¿äÄ¡ ¾ÊÀº CompactÇÑ Å©±â)

Power Supply
Power : 125 watts
Frequency: 20 kHz
Programmable Timer: 10 hours
Adjustable Pulse On/Off: 1 second to 1 minute
Dimensions ( W x D x H): 203 x 350 x 146 mm
Voltage: 220V, 50/60 Hz

Probes
ó¸®ÇÒ ¿ë·®¿¡ µû¶ó¼­, ÇϱâÀÇ 3°¡Áö probe Áß¿¡¼­ ¼±ÅÃÀ» ÇÏ½Ã¸é µË´Ï´Ù.

Probes 4423 4422 4435
Processing volume 200 §¡ - 5 §¢ 500 §¡ - 15 §¢ 10 §¢ - 50 §¢
Tip diameter 2 §® 3.2 §® 6.42 §®
Amplitude 200 §­ (very high) 180 §­ (high) 120 §­ (medium)


Cup Horn



Cup hornÀÇ °æ¿ì´Â ó¸®ÇÏ°íÀÚ ÇÏ´Â ¹°ÁúÀÌ Probe¿¡ Á÷Á¢ ´êÁö ¾Ê°í 󸮸¦ ÇØ¾ß ÇÒ °æ¿ì¿¡ »ç¿ëÀ» Çϴµ¥, ƯÈ÷ ¿À¿°ÀÌ ¿ì·Á°¡ µÇ°Å³ª °ø±â Áß¿¡ ³ëÃâÀÌ µÇ¾úÀ» °æ¿ì °¨¿°ÀÌ µÉ ¼ö ÀÖ´Â ¹°ÁúÀ» ó¸®ÇÒ °æ¿ì¿¡ À¯¿ëÇÕ´Ï´Ù.

Cup hornÀ» Converter¸¦ °Å²Ù·Î ¹èÄ¡¸¦ ÇÏ¿© ÀåÂøÀ» ÇÏ°í ³»ºÎ¿¡ ¹°À» ä¿ö¼­ 1.5 ml microtube ³ª 15 ml falcon tube¸¦ ³Ö¾î¼­ »ç¿ëÇÒ ¼ö ÀÖ½À´Ï´Ù.

Order no. 4608
Horn diameter 20 §®
Cup diameter 38 §®


8 Tip Probe

¾Ë·ç¹Ì´½ Coupler ¿Í 8°³ÀÇ 3 mm ¸¶ÀÌÅ©·ÎÆÁ (microtip)À¸·Î ±¸¼º

Order no. 4602
Processing volume 250§¡ - 2§¢
Tip °£°Ý 9 §®
Microtip length 17 §®


Stand & Clamp

Sound abating enclosure

ÆäÀ̽ººÏ Æ®À§ÅÍ