Home > Á¦Ç°¼Ò°³ > R&D Laboratory Equipment (¿¬±¸ & ½ÇÇè¿ë Á¦Ç°) > ÃÊÀ½Æĺлê±â/Æļâ±â-Sonicators/Ultrasonic Processors

ÃÊÀ½Æĺлê±â/Æļâ±â-Sonicators/Ultrasonic ProcessorsÀÌÀüÆäÀÌÁö

Q700

Á¦Á¶»ç
: QSONICA, USA
Cat.No.Description
Q700 Q700 Sonicator [°ßÀû¿äû]
4220 12.7 mm Replaceable tip Probe [°ßÀû¿äû]
4207 19.1 mm Replaceable tip Probe [°ßÀû¿äû]
4210 25.4 mm Replaceable tip Probe [°ßÀû¿äû]
4219 12.7 mm Solid Probe [°ßÀû¿äû]
4208 19.1 mm Solid Probe [°ßÀû¿äû]
4209 25.4 mm Solid Probe [°ßÀû¿äû]
4219S 12.7 mm Sapphire Probe [°ßÀû¿äû]
4208S 19.1 mm Sapphire Probe [°ßÀû¿äû]
4209S 25.4 mm Sapphire Probe [°ßÀû¿äû]
K-0002 Support stand & Heavy duty clamp [°ßÀû¿äû]
K-0003 Sound abating enclosure [°ßÀû¿äû]
LSJ150 Support Jack 150 x 150 mm [°ßÀû¿äû]
431C1 5.5" Cup horn with microtube rack [°ßÀû¿äû]
431B1 3" Cup horn with mcirotube rack [°ßÀû¿äû]
431MPHX Microplate Horn [°ßÀû¿äû]
The new Q700 is the most technologically advanced sonicator available today. A state-of-the-art touch sceren interface (ÅÍÄ¡ ½ºÅ©¸° ¹æ½Ä) offers intuitive control and provides a user-friendly experience. The most important feature of a Sonicator is reproducibility. Improved internal circuitry guaranttes more efficient operation, sample-to-sample consistency and most importantly, a reliable end result.
(Q700Àº ±â¼úÀûÀÎ ºÎºÐ¿¡¼­ °¡Àå ÃÖ½ÅÀÇ ÃÊÀ½ÆÄ ºÐ»ê±â/Æļâ±â ÀÔ´Ï´Ù. ÃֽŠ¹æ½ÄÀÇ ÅÍÄ¡ ½ºÅ©¸°À» ÀÌ¿ëÇÏ¿© Çõ½ÅÀûÀÎ ÄÁÆ®·Ñ°ú »ç¿ëÀÚ ÆíÀǼºÀ» Á¦°øÇÏ°í ÀÖ½À´Ï´Ù. ÃÊÀ½ÆÄ ºÐ»ê±âÀÇ °¡Àå Áß¿äÇÑ ºÎºÐÀº ÀçÇö¼ºÀÔ´Ï´Ù. ÃÖ½ÅÀÇ ³»ºÎ ȸ·Î°¡ ´õ È¿°úÀûÀÎ ¿î¿µ°ú ÀçÇö¼ºÀ» º¸ÀåÇØÁÖ°í ½Å·ÚÇÒ ¼ö ÀÖ´Â °á°ú¸¦ ¸¸µé¾î ÁÝ´Ï´Ù.)

The Q700 is the only sonicator in the market that offers full amplitude control from 1 - 100% (¿¡³ÊÁö °­µµ¸¦ 1 - 100 % Á¶Àý °¡´ÉÇÑ À¯ÀÏÇÑ ÃÊÀ½ÆÄ ºÐ»ê±â).
This enables greater control of the probe's intensity, heling to pinpoint the optimum settings for efficient sample processing. We have increased maximum power output to 700 watts making the system more durable and capable of handling even larger samples if necessary. Our new display, design improvements and added accessories make this the most sophisticated and versatile Sonicator available today.

Popular applications include nanoparticle dispersion, creating emulsions, cell lysis and homogenization.
(Q500Àº ³ª³ë¹°Áú ºÐ»ê, À¯È£, ¼¼Æ÷ ¿ëÇØ ¹× ±ÕÁúÈ­¸¦ À§ÇÑ ºÐ¾ß¿¡ »ç¿ëµÇ¾î Áý´Ï´Ù.)
³ª³ë ¹°ÁúÀÇ °æ¿ì´Â, CNT(Carbon Nano Tube), TiO2, SiO2µî ¸¹Àº ºÐ¾ß¿¡¼­ Àû¿ëÀÌ µÇ¾î Áý´Ï´Ù.)

Cup hornÀ» ÀÌ¿ëÇÏ¿© ¹ÐÆóµÈ tubes ³ª vials¿¡ ÀÖ´Â ¿©·¯°¡Áö sampleÀ» ¿¡¾î·ÎÁ¹(aerosols) ¹× ¿À¿° (cross contamination) ¹ß»ý ¾ø´Â Á¶°Ç¿¡¼­ µ¿½Ã¿¡ ó¸®ÇÒ ¼ö ÀÖ½À´Ï´Ù.
»ì±ÕµÈ(sterile) ¶Ç´Â (º´¿ø¼º ¹× Áúº´À» À¯¹ßÇÏ´Â) pathogenic sample ó¸®ÇÏ´Â ¸ñÀû¿¡ ÀÌ»óÀûÀ¸·Î Àû¿ëÀÌ µË´Ï´Ù.

°°Àº ¿ëµµ·Î, microplate hornÀ» ÀÌ¿ëÇÏ¿©, 96 well microtiter plate ¿¡ ÀÖ´Â sampleÀ» µ¿½Ã¿¡ ó¸®ÇÒ ¼ö ÀÖ½À´Ï´Ù.

Á¦Ç°¼³¸í

Programmable operation
Set time and amplitude for hands free operation
(½Ã°£ ¼³Á¤, ¿¡³ÊÁö °­µµ µîÀ» ¼³Á¤ÇÒ ¼ö ÀÖ½À´Ï´Ù.)

Pulse mode
Prevent heat buildup in temperature sensitive samples
(¿Âµµ¿¡ ¹Î°¨ÇÑ sample¿¡ ´ëÇؼ­ °ú´ÙÇÑ ¿­ ¹ß»ý ¹æÁö¸¦ À§ÇØ Pulse¸¦ ÀÌ¿ëÇؼ­ ÃÊÀ½ÆÄ µ¿ÀÛ 1ÃÊ¿¡¼­ 59ÃÊ ¹üÀ§ ³»¿¡¼­ Á¶Àý °¡´ÉÇÕ´Ï´Ù.)

Digital amplitude / intensity control
Output intensity can be set from 20-100%
(¿¡³ÊÁö ¼¼±â¸¦ 20 - 100% Á¶ÀýÀÌ °¡´ÉÇÕ´Ï´Ù.)

Elapsed time indicator
Displays duration of sonication
(¼³Á¤ÇÑ ½Ã°£ °æ°ú¸¦ ³ªÅ¸³»¾î ¾î´À Á¤µµ µ¿ÀÛÀÌ ÀÌ·ç¾î Áö°í ÀÖ´ÂÁö¸¦ È®ÀÎÀÌ °¡´ÉÇÕ´Ï´Ù.)

Display of wattage and joules
Real-time energy monitoring
(Sample¿¡ Àü´ÞµÇ´Â ¿¡³ÊÁö °ªÀ» È®ÀÎ ÇÒ ¼ö ÀÖ½À´Ï´Ù.)

Overload protection
Prevents damage to circuitry if a fault occurs
(¿¡·¯°¡ ¹ß»ýÇßÀ» °æ¿ì, Power supply³»ºÎ ±âÆÇÀ» º¸È£Çϱâ À§ÇØ Overload °æ°í ±â´ÉÀÌ ÀÖ½À´Ï´Ù.)

ÇϱâÀÇ ±â´ÉÀº Q700 ¸ðµ¨¸¸ÀÌ °¡Áö°í Àִ Ư¼öÇÑ ±â´ÉµéÀÔ´Ï´Ù
TOUCH SCREEN CONTROL
A large, color LCD screen clearly displays all operating parameters and options
Intuitively and quickly access any of the sonicator's fuctions with a simple touch.
(µ¿ÀÛÀ» À§ÇÑ ÀԷ°ªµéÀ» ÅÍÄ¡ ½ºÅ©¸° ¹æ½ÄÀ¸·Î ÀÔ·ÂÀ» ÇÏ´Â ¼¼°è À¯ÀÏÀÇ ÃÊÀ½ÆÄ ºÐ»ê±â ÀÔ´Ï´Ù.)




Full Amplitude Control
Amplitude (Intensity) is controlled from 1 - 100 % giving a greater degree of resoultion and the ability to pinpoint the ampltude needed to effectively process your sample.
(¿¡³ÊÁö °­µµ¸¦ 20%¿¡¼­°¡ ¾Æ´Ï¶ó 1%¿¡¼­ ¼³Á¤ÀÌ °¡´ÉÇϸç ÃÖ´ë 100% ¼³Á¤ÀÌ °¡´ÉÇÑ ¼¼°è À¯ÀÏÀÇ ÃÊÀ½ÆÄ ºÐ»ê±â ÀÔ´Ï´Ù.)


Temperature Monitoring
Temperature probe is available for those customers who wish to monitor the temperature of their sample.
If the temperature limit is reached, sonication shuts down to prevent overheating.
(¿Âµµ ¼¾¼­¸¦ ºÎÂøÇÏ¿© »ç¿ëÀÌ °¡´ÉÇÏ¿© ¼³Á¤ ¿Âµµ ÀÌ»óÀÌ ³Ñ¾î¼­¸é µ¿ÀÛÀÌ ¸ØÃß°Ô µÇ¾î ¿Âµµ¿¡ ¹Î°¨ÇÑ ¹°ÁúÀ» ó¸®ÇÒ ¶§ À¯¿ëÇÏ°Ô »ç¿ëÀÌ µÉ ¼ö ÀÖ´Ù.)


Run Multiple Programs In Sequence
Multiple programs can be in sequence. For exampl, the unit can be programmed to sonicate at 50% amplitud for 5 minutes, shut off for 2 minutes and re-start at 25% amplitude for 10 minutes. Up to 6 programs can be run in succsssion.
(ÃÖ´ë 6°¡Áö ¼³Á¤ ÀԷ°ªµéÀ» ÇϳªÀÇ ÇÁ·Î±×·¥À¸·Î ÀúÀåÀ» ÇÏ¿© ¿¬¼ÓÀûÀ¸·Î »ç¿ëÇÒ ¼ö ÀÖÀ¸¸ç, ÃÖ´ë ÇÁ·Î±×·¥À» 2°³ ¸¸µé ¼ö ÀÖ½À´Ï´Ù. ÀÌ ÇÁ·Î±×·¥°ú´Â º°°³·Î, °³º°ÀûÀÎ ÀԷ°ªÀ» ÃÖ´ë 10°³ (0¹ø - 9¹ø)±îÁö ÀúÀåÀÌ °¡´ÉÇϸç, ÀúÀåÇÑ ÀԷ¹øÈ£ (0 - 9)À» ºÒ·¯µé·Á »ç¿ëÀÌ °¡´ÉÇÏ¿© ¹Ýº¹ÀûÀ¸·Î ÀÌ·ç¾îÁö´Â ½ÇÇè¿¡¼­´Â »õ·Î ÀԷ°ªÀ» ¼³Á¤ÇÒ ÇÊ¿ä°¡ ¾ø½À´Ï´Ù.)



¿¹) Çϱâ¿Í °°ÀÌ 5°¡ÁöÀÇ ProgramÀÌ Sequence 1¿¡ ÀúÀåÇÏ¿´°í, ÀúÀåµÈ ProgramÀÌ 1 - 5±îÁö ¿¬¼ÓÀûÀ¸·Î ÀÚµ¿ µ¿ÀÛÀÌ µÈ´Ù.
program°ú ´ÙÀ½ program »çÀÌ¿¡ Delay timeÀ» ¼³Á¤ÇÏ¿© Delay timeÀÌ Áö³­ ÈÄ ´Ù½Ã µ¿ÀÛÀ» ÇÑ´Ù.
2°³ÀÇ ÇÁ·Î±×·¥À» ¿¬¼ÓÀûÀ¸·Î ÀúÀåÇØ µÑ ¼ö À־, ÀúÀåÇÑ Sequence¸¦ ºÒ·¯µé¿©¼­ »ç¿ëÇÒ ¼ö ÀÖÀ½À¸·Î µ¿ÀÏÇÑ Á¶°ÇÀÇ ¹Ýº¹ÀûÀÎ ½ÇÇè¿¡¼­ »ó´çÈ÷ Æí¸®ÇÏ´Ù.

SEQUENCE 1

Program 1
Amplitude - 30 %
Process time - 00 : 01 : 00
Process-ON time - 00 : 00 : 03
Process-OFF time - 00 : 00 : 01
Delay time

Program 2
Amplitude - 50 %
Process time - 00 : 01 : 30
Process-ON time - 00 : 00 : 02
Process-OFF time - 00 : 00 : 02
Delay time

Program 3
Amplitude - 80 %
Process time - 00 : 02 : 00
Process-ON time - 00 : 00 : 05
Process-OFF time - 00 : 00 : 02
Delay time

Program 4
Amplitude - 60 %
Process time - 00 : 03 : 00
Process-ON time - 00 : 00 : 04
Process-OFF time - 00 : 00 : 02
Delay time

Program 5
Amplitude - 40 %
Process time - 00 : 01 : 30
Process-ON time - 00 : 00 : 03
Process-OFF time - 00 : 00 : 01



Large Disply
µ¿ÀÛ Áß¿¡´Â Screen¿¡¼­ À§ÀÇ ±×¸²°ú °°ÀÌ ¸ðµç ÀÔ·Â Á¤º¸¸¦ ÇÑ ´«¿¡ º¼¼ö°¡ ÀÖ¾î »ç¿ëÀÚ¿¡°Ô »ó´çÈ÷ Æí¸®ÇÏ´Ù.
- Amplitude
- Process time
- Elasped time
- Pulse ON time
- Pulse OFF time
- Probe temperature
- Shutdown temperature
- Power to sample
- Accumulated energy
- Program progress %



[Application Video]

ÃÊÀ½ÆÄ¿¡³ÊÁö¸¦ ÀÌ¿ëÇÏ¿© ¹°¿¡ Ä«º»³ª³ëÆ©ºê¸¦ ºÐ»êÇÏ´Â µ¿¿µ»óÀÔ´Ï´Ù. (¹° 1,200ml¿¡ Ä«º»³ª³ëÆ©ºê 1.2g ºÐ»ê)
ÃÊÀ½ÆĺлêÀº ³ª³ëÀÔÀÚÀÇ ³ª³ëºÐ»ê¿¡ ÃÖÀûÀÎ ¹æ¹ýÀÔ´Ï´Ù.

Specification

Power Supply
Power : 700 watts
Frequency: 20 kHz
Programmability: 10 memories + 2 sequencing (10°³ÀÇ ¸Þ¸ð¸® + 2°³ÀÇ ÇÁ·Î±×·¥ ÀúÀå °¡´É)
Programmable Timer: 72 hours
Adjustable Pulse On/Off: 1 second to 24 hours
Dimensions (W x D x H): 230 x 387 x 216 mm
Voltage: 220V, 50/60 Hz

Probes
ÇϱâÀÇ Probe Áß Sapphire probe¸¦ Á¦¿ÜÇÑ ÇϳªÀÇ probe´Â ÁÖ¹®½Ã Standard Probe·Î ¼±ÅÃÀÌ °¡´ÉÇÕ´Ï´Ù.
Order no. 4220 Order no. 4219 Order no. 4219S Order no. 4207 Order no. 4208 Order no. 4208S Order no. 4210 Order no. 4209 Order no. 4209S
Replaceable tip Solid tip Sapphire tip Replaceable tip Solid tip Sapphire tip Replaceable tip Solid tip Sapphire tip
Processing volume
10 - 250 ml
Processing volume
10 - 250 ml
Processing volume
10 - 250 ml
Processing volume
25 - 500 ml
Processing volume
25 - 500 ml
Processing volume
25 - 500 ml
Processing volume
50 - 1000 ml
Processing volume
50 - 1000 ml
Processing volume
50 - 1000 ml
Tip diameter
12.7 mm
Tip diameter
12.7 mm
Tip diameter
12.7 mm
Tip diameter
19.1 mm
Tip diameter
19.1 mm
Tip diameter
19.1 mm
Tip diameter
25.4 mm
Tip diameter
25.4 mm
Tip diameter
25.4 mm

Accessories
for (4220), (4207), (4210) Replaceable Probes


Order no. 4406 Order no. 4407 Order no. 4408
Tip diameter
12.7 mm
Tip diameter
19.1 mm
Tip diameter
25.4 mm


Microtip Probes
¾Æ·¡ÀÇ Microtip probeµéÀº 4220 (13 mm replaceable tip probe) - 12.7 mm probe¿Í ¿¬°áÇؼ­ ¼Ò·®À» ó¸®ÇÒ ¶§ »ç¿ëÀÌ °¡´ÉÇÕ´Ï´Ù.
Order No.4417 Order No. 4418 Order No. 4420
Tapered Microtip Tapered Microtip Tapered Microtip
Processing volume
0.2 - 5 ml
Processing volume
0.2 - 15 ml
Processing volume
5 - 50 ml
Tip diameter
1.6 mm
Tip diameter
3.2 mm
Tip diameter
6.4 mm

¾Æ·¡ÀÇ Stepped microtipÀº 4220 Replaceable tip probe 12.7 mm probe¿¡ ¿¬°áÇÏ´Â °ÍÀÌ ¾Æ´Ï¶ó, Converter¿¡ 4221 Coupler¸¦ ÀåÂøÇÏ°í Coupler¿¡ ¿¬°áÇÏ¿© »ç¿ëÀ» ÇÏ¿©¾ß ÇÑ´Ù.
Order no. 4421 Order no. 4422
Coupler Stepped Microtip
Processing volume
0.5 - 15 ml
Tip diameter
3.2 mm

Extenders
Standard probesÀÇ °æ¿ì, ±æÀÌ°¡ ÃæºÐÈ÷ ±æÁö ¾Ê¾Æ¼­ ÀϺΠ±íÀÌ°¡ ±íÀº Vessel¿¡¼­´Â »ç¿ëÀ» ÇϱⰡ °ï¶õÇÏ´Ù.
ÀÌ·± °æ¿ì¿¡ Tip diameter°¡ °°Àº Standard probe¿¡¼­ TipÀ» »©°í Extenders¸¦ ¿¬°áÇؼ­ »ç¿ëÀÌ °¡´ÉÇÏ´Ù.
ExtendersÀÇ °æ¿ì ±æÀÌ°¡ 127 mm (5") ¿Í 254 mm (10")°¡ °¡´ÉÇϸç solid type °ú replaceable type ÀÌ °¡´ÉÇÕ´Ï´Ù.
Order no. Type of Tip Length Tip Diameter
406HW Solid 127 mm 12.7 mm
406HWT Replaceable tip 127 mm 12.7 mm
407HW Solid 127 mm 19.1 mm
407HWT Replaceable tip 127 mm 19.1 mm
408HW Solid 127 mm 25.4 mm
408HWT Replaceable tip 127 mm 25.4 mm
406FW Solid 254 mm 12.7 mm
406FWT Replaceable tip 254 mm 12.7 mm
407FW Solid 254 mm 19.1 mm
407FWT Replaceable tip 254 mm 19.1 mm
408FW Solid 254 mm 25.4 mm
408FWT Replaceable tip 254 mm 25.4 mm

Boosters (Order no. 4121)
Booster´Â 19.1 mm ¶Ç´Â 25,4 mm probe ¿¡¼­ »ç¿ëÀÌ °¡´ÉÇϸç Intensity¸¦ ³ôÀ̱â À§Çؼ­ »ç¿ëµÇ¾îÁø´Ù.
Converter ¿Í Probe »çÀÌ¿¡ ¿¬°áÀ» Çؼ­ »ç¿ëÇÏ¸ç »ç¿ë Àü¿¡ ºñÇØ ¾à 2¹è Á¤µµÀÇ Intensity°¡ Áõ°¡µË´Ï´Ù.

High Gain Probes
High Gain Probes ¿ª½Ã 19.1 mm ¶Ç´Â 25.4 mm Standard probes¸¦ »ç¿ëÇßÀ»¶§º¸´Ù ¾à 2¹è Á¤µµÀÇ Instensity¸¦ ¹ß»ýÇÑ´Ù.
Converter¿¡ ¹Ù·Î ¿¬°áÇÏ¿© »ç¿ëÀ» ÇϸéµÇ¸ç Booster¿Í ÇÔ²² »ç¿ëÀº ÇÒ ¼ö ¾ø½À´Ï´Ù.
Á¾·ù´Â Solid type°ú Replaceable typeÀÌ ÀÖ½À´Ï´Ù.
Order no. Type of Tip Processing Volume Tip diameter Amplitude
4305 Replaceable type 25 - 500 ml 19.1 mm 120 um
4306 Solid type 25 - 500 ml 19.1 mm 120 um
4310 Solid type 50 - 1000 ml 25.4 mm 60 um
4311 Replaceable type 50 - 1000 ml 25.4 mm 60 um

Footswitch (Order no. 4004)
Enables hands free opration


Temperature Monitoring

Flexible thermocouple (Order no. 4103)
Temperature sensor (Order no. 4102)

Support stand & Heavy duty clamp


Sound abating enclosure


cup horn

inner diameter of cup : 3 " (= 7.62 mm)
diameter of horn : 2.5" (= 6.35 mm)
tube capacity : 8 ea


inner diameter of cup : 5.5 " (= 13.97 mm)
diameter of horn : 2.5" (= 6.35 mm)
tube capacity : 20 ea

Mircotplate horn
ÆäÀ̽ººÏ Æ®À§ÅÍ